What to do if the floor heating circuit is uneven
Floor heating systems are becoming more and more popular in modern homes, but many users have reported uneven floor heating circuits, causing the temperature in some rooms to be too high or too low. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the causes and solutions of uneven floor heating circuits.
1. Common causes of uneven floor heating circuits

| Reason | Specific performance |
|---|---|
| Unreasonable pipeline design | The difference in loop length is too large, resulting in uneven distribution of water flow |
| clogged pipes | The accumulation of impurities or scale affects the smooth flow of water |
| Water distributor failure | The valve is damaged or improperly adjusted, resulting in uneven flow distribution. |
| Insufficient system pressure | Insufficient water pump power or improper pressure adjustment |
2. Solutions to uneven floor heating circuits
1.Check piping design
If the length of the floor heating circuits is too different, it is recommended to redesign the pipe layout to ensure that the lengths of each circuit are similar. The professional installation team will make reasonable planning based on the area and structure of the house.
2.Clean pipes
Regular cleaning of underfloor heating pipes is key to avoiding blockages. The following are common cleaning methods:
| Cleaning method | Applicable situations |
|---|---|
| chemical cleaning | Suitable for scale and minor blockages |
| High pressure washing | Suitable for severe blockage or impurity accumulation |
| Pulse cleaning | Suitable for complex piping systems |
3.Adjust the water distributor
The water distributor is the core component of the floor heating system. Improper adjustment will lead to uneven flow distribution. The following are the adjustment steps:
- Close all circuit valves
- Open the circuits one by one and observe the temperature changes
- Adjust the valve opening according to room needs
4.Check system pressure
Insufficient system pressure will cause slow water flow and affect the heating effect. It is recommended to check the working status of the water pump and ensure that the pressure is between 1.5-2.0Bar.
3. Measures to prevent uneven floor heating circuits
1.Regular maintenance
It is recommended that the floor heating system be fully inspected every year before the heating season, including pipes, water distributors, water pumps and other components.
2.Install filter
Installing a filter at the water inlet can effectively prevent impurities from entering the pipeline and extend the service life of the system.
3.Use demineralized water
Hard water easily produces scale, so it is recommended to use softened water as circulating water for floor heating systems.
4. User FAQs
| question | Answer |
|---|---|
| What should I do if the floor heating part of the room is not hot? | First check whether the circuit valve is fully open, and then check whether there is any blockage. |
| What is the reason why the floor heating temperature fluctuates between high and low? | It may be that the system pressure is unstable or the water distributor is improperly adjusted. |
| What should I do if the circuit becomes uneven after newly installed floor heating? | The installation company should be contacted immediately to check the pipeline design and construction quality |
5. Professional advice
If the problem is not solved after self-adjustment, it is recommended to contact a professional floor heating repairman. The floor heating system involves many aspects such as water and electricity, and improper operation may lead to more serious problems.
Through the above analysis and solutions, I believe you have a deeper understanding of the problem of uneven floor heating circuits. Regular maintenance and correct use are key to ensuring efficient operation of your floor heating system.